Compact SMVR that opens the future with new challenges
SMVR ProductsTest result
NO. | Item | Unit | Limitation on malignant wastewater for a specific region in Korea |
Requested test to certified institute after purifying malignant wastewater of plating factory with MVR facility. |
|||||
---|---|---|---|---|---|---|---|---|---|
Test result of Korea Institute of Chemistry : Very good (best water quality) |
|||||||||
Clean Area | “A” Area | “B” Area | Special Area | Influx | Efflux | Water Purification Rate(%) | |||
1 | BOD | ㎎/ℓ | 40 | 80 | 120 | 30 | 79.4 | 9.1 | 88.5 |
2 | CODMn | ㎎/ℓ | 50 | 90 | 130 | 40 | 484 | 28.3 | 94.2 |
3 | SS | ㎎/ℓ | 40 | 80 | 120 | 30 | 186 | 2.0 | 98.9 |
4 | T-N | ㎎/ℓ | 30 | 60 | 60 | 60 | 504 | 6.01 | 98.8 |
5 | T-P | ㎎/ℓ | 4 | 8 | 8 | 8 | 0.85 | 0.05 | 94.1 |
6 | CN | ㎎/ℓ | 0.2 | 1 | 1 | 1 | ND | ND | - |
7 | Cr | ㎎/ℓ | 0.5 | 2 | 2 | 2 | 1.42 | 0.02 | 98.6 |
8 | Fe | ㎎/ℓ | 2 | 10 | 10 | 10 | 62.2 | 0.14 | 99.8 |
9 | Zn | ㎎/ℓ | 1 | 5 | 5 | 5 | 183 | 0.11 | 99.9 |
10 | Cu | ㎎/ℓ | 1 | 3 | 3 | 3 | 0.07 | 0.03 | 57.1 |
11 | pH | - | 5.8 ~ 8.6 | 5.8 ~ 8.6 | 5.8 ~ 8.6 | 5.8 ~ 8.6 | 5.7 | 6.8 | - |
12 | Conductivity | ㎲/㎝ | Reference | 24,700 | 57 | 99.8 | |||
13 | Na | ㎲/㎝ | Reference | 5,180 | 1.77 | 100.0 | |||
14 | Ni | ㎲/㎝ | Reference | 1.41 | 0.02 | 98.6 | |||
15 | TDS | ㎲/㎝ | Reference | 16,300 | 48.0 | 99.7 |